    Analisa Kerusakan Pompa OCCWP Pada Pembangkit Listrik Tenaga Uap 2 x 115 MW

    No Thumbnail [100%x160]
    View/Open
    Analisa Kerusakan Pompa OCCWP Pada Pembangkit Listrik Tenaga Uap 2 x 115 MW.pdf (909.6Kb)
    Date
    2021-08-01
    Author
    Sianturi, Tambos August
    Hutauruk, Sindak
    Sihombing, Fiktor
    Metadata
    Show full item record
    Abstract
    The use of pumps in the industrial world, especially in power plants, cannot be separated from problems that arise that can cause losses. The research was conducted at PLTU 2 X 115 MW by taking a case that had happened to the pump, namely the Open Cycle Cooling Water Pump 2A. The analytical method used in this final project is the vibration analysis method, namely by reading the spectrum of the data retrieval results so that it can be seen what happens to the equipment that experiences an increase in vibration. Bearing damage can be seen in the spectrum image of the measurement results, where the appearance of the spectrum in the high frequency range is an indication of bearing damage. And the high vibration which reaches 13.06 mm/s and is already in the danger category based on ISO 10816-3.
    URI
    http://repository.uhn.ac.id/handle/123456789/5371
    Collections
    • LP - National Published Articles [249]

    Repository UHN copyright © 2018  UHN-OFFICIAL
    Contact Us | Send Feedback
     

     

    Browse

    All of Repository UHNCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Repository UHN copyright © 2018  UHN-OFFICIAL
    Contact Us | Send Feedback
     

     

    NoThumbnail